Learn@UW - Issue with Configuration Variable Controlling Gradebook Import

This document is for Site Administrators only.

In the Config Variable Browser tool, the variable controlling the number of records per batch when importing a gradebook cannot be set.

The configuration variable d2l.Tools.Grades.Import.NumRecordsPerImportStep allows an administrator to specify the number of records imported in each batch when importing a gradebook. If you attempt to edit this variable, you cannot specify a value in the window. A drop-down menu displays no values. The Save and Cancel buttons are also unresponsive. This means you cannot change the current value.

This is a known issue.

In prior versions of the Learning Environment, any value specified for the org unit was NOT ENFORCED by the system. In version 10.3, this value IS ENFORCED. If a limit has been specified, users may experience errors in version 10.3 that were not seen under prior versions. The current recommendation is to delete any specified value which will allow the default value of 10000 to take effect.



Keywords:brightspace learn@uw learnuw d2l desire2learn grades config configuration variable number record import known issue   Doc ID:40630
Owner:Susan D.Group:Learn@UW Utility
Created:2014-06-03 09:33 CDTUpdated:2015-06-03 16:08 CDT
Sites:DoIT Help Desk, DoIT Tech Store, Learn@UW Madison, Learn@UW Utility
Feedback:  0   0