  • Building

    If you cannot find your location on the drop down menu, try looking it up by building number: https://facilities.fpm.wisc.edu/facility-list/. If you still cannot find your location, enter it in the text box “Building other” provided.

    To the top

    Room

    Multiple rooms can be listed as a single entry if they have the same use, biosafety level, and containment equipment.

    For animals listed on the protocol that are maintained via another entity on campus (such as in WIMR), listing the room number as “vivarium” is acceptable. It is possible during the protocol review by OBS, that you may be asked to provide a specific room number for animal work.

    All rooms used to house materials listed on your protocol or used for research-related purposes should be listed.  Examples can include: autoclave rooms, collaborator’s space (if listed personnel will be working in the collaborator’s space with listed material), core facility rooms, and vivariums.    

    To the top

    Biosafety Level

    To determine if your space meets the criteria for a particular biosafety level, please review the NIH Guidelines and the BMBL: Biosafety in Microbiological and Biomedical Laboratories (BMBL) 6th Edition.

    If you share a space and higher biosafety level work is occurring in the space, all work must be performed at the higher biosafety level. (UW-Madison Institutional Biosafety Committee Policy UW-6102

    To the top

    Examples

    Building

    Room #

    Room Use

    Biosafety Level

    Containment Equipment

    Annual Certification

    Clinical Science Center

    20

    Other – Refrigerators and freezers located in this room

    Not applicable (non-laboratory area)

    Not applicable

     

    Clinical Science Center

    456

    Laboratory

    BSL2

    Biological safety cabinet (BSC)

    Yes

    Greenhouse-Walnut St

    3

    Plant procedures/plant growth

    BSL1-P

    Not applicable

     

    Microbial Sciences Building

    25

    Incubator room-Controlled temperature room for bacterial plates/cultures

    BSL1

    Not applicable

     

    Microbial Sciences Building

    32

    Cold room or freezer room-Cold room

    BSL1

    Not applicable

     

    Microbial Sciences Building

    48

    Autoclave area

    Not applicable (non-laboratory area)

    Not applicable

     

    Service Memorial Institute

    62

    Cold room or freezer room-Walk-in freezer

    BSL2

    Not applicable

     

    Wisconsin Institutes for Medical Research

    B13

    Core facility (Shared area with specialized research support equipment; e.g., Flow cytometry, CMN, SMSSF, etc.)

    ABSL2, BSL2

    Biological safety cabinet (BSC)

    Yes

    Wisconsin Institutes for Medical Research

    B14

    Animal procedures/housing

    ABSL2

    Biological safety cabinet (BSC), Ventilated HEPA-filtered housing or rack system

    Yes

    Still have questions? Call the Office of Biological Safety (OBS) at 608-263-2037. We are happy to help.